BALL VALVE HIGHLIGHTS Ball valves

PNEUMATIC CONTROL HEADS TYPE-AT-F (SINGLE-ACTING)

Control pressuremin. 3,5 bar – max. 8 bar
Setting angle
90°for G and GL types
NCNormally closed
NOnormally open
180°for GLU types
Temperature
Viton O-Ringemax. 150°C
The pneumatic actuator type AT-F with automatic spring return is ideal for automating VSM ball valves. A mounting kit fits all series 12, 16 and 18 ball valves, from 1/16″ to 15 mm pipe outside diameter.

PNEUMATIC CONTROL HEADS TYPE-AT-D (DOUBLE-ACTING)

Control pressuremin. 2,5 bar – max. 8 bar
Setting angle 
90°for G and GL types
180°for GLU types
Temperature 
Viton O-Ringemax. 150°C

The pneumatic actuator type AT-D is ideal for automating VSM ball valves. A mounting kit fits all series 12, 16 and 18 ball valves, from 1/16″ to 15 mm pipe outside diameter.

ASSEMBLY INSTRUCTIONS FOR PNEUMATIC CONTROL HEADS

ASSEMBLY INSTRUCTIONS

1Loosen the 4 nuts (1)
2Remove actuator with bolt from the mounting plate (2)
3Place the new actuator with bolts in the exact position on the mounting plate (2)
4Fit the mounting bracket (5)
5Tighten the 4 nuts
6The coupling (3) must be loosely mounted on the ball valve spindle
7Securing via lock nuts (4)